Applicable mediumLiquid fluid, slurry, suspension, high viscosity fluid, etc.
Not applicable medium Solid medium
84409900 / 84403377
Overview:
YS-MFU series high pressure mass flow meter is based on the principle of Coriolis Force to realize the direct and precise measurement of fluid mass flow without any conversion or correction of pressure, temperature, viscosity and density. The inner connecting pipe is made of thin-walled precision stainless steel pipe.The working principle of the mass flowmeter determines that the pressure fluctuation of the pipe fluid has no influence on the precision, at the same time, the high-pressure welding process and equipment ensure the instrument itself can withstand the field high-pressure fluid safe flow and stable measurement.
Product features:
●A multivariable digital processing system is used. The application of the multivariable digital processing system strengthens the filtering of the signal, improves the sensitivity and accuracy of the signal measurement, speeds up the response time of the system and makes the measurement more reliable
●Coupled vibration isolation technology, easy installation without rectification and straight pipe section;
●The measurement accuracy is high, the general mass flow measurement accuracy can reach 0.1%-0.2% , the density measurement resolution can reach 0.002-0.02 G/CM, the temperature measurement error is less than 0.5 degrees;
●Long-term calibration sensor and transmitter storage data, debugging program without initialization;
Reference Range table for high pressure mass flowmeter:
Model number | Path path (mm) | Recommended traffic range(kg/h) | Maximum flow range (kg/ h) |
YS-MFU-003 | 3 | 0-150 | 0-180 |
YS-MFU-006 | 6 | 0-480 | 0-960 |
YS-MFU-010 | 10 | 0-1800 | 0-2100 |
YS-MFU-015 | 15 | 0-3600 | 0-4500 |
YS-MFU-020 | 20 | 0-6000 | 0-7200 |
YS-MFU-025 | 25 | 0-9600 | 0-12000 |
YS-MFU-032 | 32 | 0-18000 | 0- 21000 |
YS-MFU-040 | 40 | 0-30000 | 0-36000 |
YS-MFU-050 | 50 | 0-48000 | 0-60000 |
YS-MFU-080 | 80 | 0-150000 | 0-180000 |
YS-MFU-100 | 100 | 0-240000 | 0-280000 |
YS-MFU-150 | 150 | 0-480000 | 0-600000 |
Reference Range table for high pressure mass flowmeter:
●Accuracy of flow measurement | : | ±0.1-0.2% |
●Repeatability | : | ±0.05-0.1% |
●Repeatability | : | 0< ρ < 5g/ cm³ |
●Accuracy of density measurement | : | ±0.002g/cm³ |
●Temperature range | : | -200~350℃ |
●Accuracy of temperature measurement | : | ±1℃ |
●Measured medium temperature | : | -50℃ ~ 200℃ |
●Applicable ambient temperature | : | -40℃ ~80℃ |
●Material Quality | : | Fluid Connection, 316L housing, 304 |
●Working pressure | : | Conventional 4MPA, high pressure can be customized |
●Output Signal | : | 4-20mA DC current signal, 0-10KHz frequency pulse signal, |
Pulse equivalent signal, RS485 communication signal | ||
●Explosion proof grade | : | Exd(ib) II CT6 |
●Protection | : | IP67 |